What it takes to rebuild a landfill's prediction limits from public data

13 November 2026 · about a six minute read

If background is a new term, start with what "background" means in landfill groundwater monitoring.

A filed groundwater monitoring report is a public record, and so, in California, is much of the laboratory data behind it. That raises a fair question for anyone checking a statistics program: can you take the public data, run the same method the report describes, and get the same numbers? We tried it on one landfill's report. The first attempt matched 3 limits out of 25. The second matched all 31. This article explains what changed between them, because the reason applies to almost any site.

The landfill is a municipal solid waste landfill regulated under RCRA Subtitle D, the part of the Resource Conservation and Recovery Act that governs those landfills, with the federal groundwater rules in 40 CFR Part 258, Subpart E. California adds its own requirements, and each facility's waste discharge requirements set details such as the retest rule. Another facility's program may differ, so treat the method below as this site's, not as a rule.

The report we checked

Riverside County Department of Waste Resources filed the semi-annual groundwater report for Badlands Sanitary Landfill on 30 April 2026. It is on GeoTracker, the State Water Resources Control Board's public database. Appendix L of the report holds 31 intrawell prediction limits for the sampling event of 5 and 10 February 2026. A prediction limit is the highest value a new result can take before it counts as a potential increase. Intrawell means each well is compared with its own earlier results, rather than with upgradient wells.

The limits were made with Sanitas, a widely used groundwater statistics program. They cover boron, chloride, nitrate as N, pH (an upper and a lower limit), potassium, sulfate and total dissolved solids, at five wells: BL-03, BH-11, BD-04, BH-22 and BH-25. The report states the method:

EPA's Unified Guidance, the agency's guidance on the statistics these rules require, describes this family of methods in chapters 18 and 19.

First attempt: the public lab data

GeoTracker publishes laboratory results county by county as downloadable files. We loaded the file for this landfill's county and took every reading before the February 2026 event as background, the history each new result is compared with.

Only 3 of 25 comparable limits matched. The six pH limits could not be compared at all: pH is measured in the field, and GeoTracker's file holds laboratory results. In almost every other row, the number of background readings was different from the number the county printed.

Why the public data did not match

Nothing was wrong with the county's limits. The public file simply does not hold the same background the county used.

One reading, correctly set aside by the people who know the site, moves that limit from 1.25 to 21 mg/L. No method choice can recover that from the public data alone. It is a judgment recorded somewhere other than the lab file.

Second attempt: the background printed in the report

Appendix L prints the background readings behind each limit, 1,363 readings in all. We loaded those exactly as printed and ran the same method.

All 31 of 31 limits agree with the county's to the precision the report prints. Each one also has the same form, parametric or nonparametric, the same transformation (a square root for nitrate at BH-22, for example), and the same number of background readings. Where the report gives the share of background below the detection limit, that agrees too: 55.42% for nitrate at BL-03. Some examples, county first and Koyna second:

The full table, row by row, is on our page comparing Koyna against filed reports.

What this says about any site

A filed limit can be rebuilt from public data only when its background can be rebuilt. The arithmetic of a prediction limit is short. The background is where the work, and the judgment, sits. The usual reasons the background cannot be rebuilt from a public lab file are:

So the best source for checking a limit is the facility's own data file. The next best is a report that prints its background readings, as this one does. A public lab file on its own is a good place to see recent results, and a poor place to reproduce a limit set from decades of screened history.

Reading GeoTracker's file as it is written

One practical note for anyone who tries this. Koyna reads GeoTracker's county file in the form GeoTracker writes it: values such as ".5" without a leading zero, the yes or no column that says whether a substance was not detected, and GeoTracker's substance codes, which Koyna turns into names using GeoTracker's own list of valid values.

What Koyna does today

Koyna loads a facility's whole history from a CSV or Excel file, with a step where you match the file's columns to what Koyna expects. It computes intrawell and interwell prediction limits, with the form chosen by a normality test, and prints method codes in the style Sanitas uses, such as "NP Intra (normality)". Each result keeps the background it was computed from, the method version and the software version, so it can be checked again later against the same inputs.

If you have rebuilt limits from public data and found something different, or if this does not match how background is kept at your facilities, we would like to hear it. Write to support@koynasystems.com.

Sources

  • Riverside County Department of Waste Resources, semi-annual groundwater monitoring report for Badlands Sanitary Landfill, filed 30 April 2026, Appendix L. GeoTracker global id L10003146754. GeoTracker
  • GeoTracker laboratory data downloads by county. GeoTracker
  • 40 CFR Part 258, Subpart E, the groundwater monitoring rules for municipal solid waste landfills. eCFR
  • US EPA, Statistical Analysis of Groundwater Monitoring Data at RCRA Facilities: Unified Guidance, EPA 530-R-09-007, March 2009. Chapter 5 on background, chapter 18 on prediction limits and chapter 19 on retesting. PDF

Sanitas is a trademark of its owner. Koyna Systems is not affiliated with Sanitas or its owner, and nothing here is endorsed by them.