KOYNA RCRA GROUNDWATER STATISTICS & REPORTING

CHECKED AGAINST FILED REPORTS

How to read the statistics appendix in a landfill groundwater report

13 November 2026 · about an eight minute read

Many semiannual groundwater reports for California landfills carry an appendix of prediction limit tables printed by Sanitas, a Windows statistics program widely used for this work. Each row compares one new result at one well with a limit computed from background, the earlier results that represent water the landfill has not affected. This article explains every column and every method code in those tables, using real rows from two reports anyone can download.

It covers municipal solid waste landfills under RCRA Subtitle D, the part of the Resource Conservation and Recovery Act whose groundwater rules are in 40 CFR Part 258, Subpart E. Both example reports are from California, where state rules and each facility's waste discharge requirements add to the federal rule. Your facility's program may differ, and its permit decides the retest rule.

The two reports are:

The columns

The method codes

Every code says two things: parametric or nonparametric, and intrawell or interwell. Interwell means the well is compared with background pooled from other wells, usually upgradient ones.

Why a nonparametric alpha is not 0.01

For a parametric limit the alpha is chosen, and the multiple is computed to match it. For a nonparametric limit it is the other way round. The limit is a background reading, so the only thing that can change the false positive rate is how many readings there are and which one is used. Section 18.3 of the guidance explains this: the confidence of a nonparametric limit follows from n and the retest plan, and cannot be set freely.

The Badlands rows show it. If the limit is the highest of n background readings, the chance that one new reading from the same water lands above it is 1 in n + 1:

The 1-of-2 plan means a first exceedance is followed by one resample, and an increase is confirmed only if the resample also exceeds. The resample is what keeps the overall false positive rate acceptable when one reading alone carries 3 percent. A small n gives a large alpha, which is one reason the guidance asks for more background over time.

The false positive rate line

Some appendices add a line under the table giving the false positive rate across all of its rows. One well and one constituent is a single test, but a site runs dozens or hundreds of them each event, and some will exceed by chance. The guidance recommends a site-wide false positive rate of 10 percent a year across all tests, and chapter 19 explains how retesting reaches that target while each test keeps enough power to catch a real release. The line tells a reviewer what rate the per-row alphas were chosen to add up to.

Reading the Visalia stages

The Visalia appendix runs the same data through three stages, and the same well can appear in each.

How Koyna handles these tables

Koyna prints prediction limit tables with the same columns and the same method codes, so an engineer or reviewer who knows the Sanitas appendix can read Koyna's without learning a new layout. We ran Koyna on two filed reports, and its numbers agree with the Sanitas tables: all 31 of 31 limits in the Badlands appendix and all 79 of 79 rows in the Visalia appendix. The comparison is written up in Koyna against filed reports.

If something here does not match how you read or prepare these appendices, or a column means something different in your reports, we would like to hear it. Write to support@koynasystems.com.

Sources

  • US EPA, Statistical Analysis of Groundwater Monitoring Data at RCRA Facilities: Unified Guidance, EPA 530-R-09-007, March 2009. Chapter 14 on seasonality; chapter 15 on nondetects; chapter 18 on prediction limits, including equation 18.3 for the parametric limit and section 18.3 for nonparametric limits; chapter 19 on retesting and the site-wide false positive rate. PDF
  • 40 CFR § 258.53, which lists the statistical methods allowed, prediction intervals among them, and the standards they must meet. eCFR
  • Badlands Sanitary Landfill, Riverside County, groundwater monitoring report filed 30 April 2026, Appendix L; and Visalia Landfill, Tulare County, First Semi-Annual 2026 report, Appendix C-5. Both are public on the State Water Resources Control Board's GeoTracker. GeoTracker

Sanitas is a trademark of its owner. Koyna Systems is not affiliated with Sanitas or its owner, and nothing here is endorsed by them.